LectroCount Electronic Registers - Specifications
|
REPEATABLILITY: Capable of .03% of reading over entire range.
| LINEARITY: |
Capable of ±0.10%
or better over a 5:1 range from maximum nominal meter
capacity. |
| LINEARITY: |
Capable of ±0.10%
or better over a 10:1 range from maximum nominal meter
capacity. |
| LINEARITY: |
Capable of ±0.15%
or better over a 40:1 range from maximum nominal meter
capacity. |
|
|
|
Due to the capabilities of multi-point calibration for meters
equipped with LectroCountElectronic Registration, superior
accuracy (linearity) can be provided as indicated above.
|
NOTE: Accuracy obtainable when all variables remain constant. Reading/
measurements must be equal to a minimum of one minute of flow at
selected rate(s). All accuracy statements based on metering Stoddard
Solvent, approximate viscosity 1 CPS. On higher viscosity products,
the average deviation in accuracy will be even less.
|